Product Details:
Contact Now
Chat Now
|
| Mountingtype: | Flange Mount | Productname: | Rexroth Plunger Pump |
|---|---|---|---|
| Material: | High-strength Steel | Shafttype: | Splined Or Keyed Shaft |
| Type: | Plunger Pump | Sealingtype: | Mechanical Seals Or Packing Seals |
| Drivetype: | Hydraulic / Mechanical | Application: | Hydraulic Systems In Industrial And Mobile Machinery |
| Highlight: | Rexroth hydraulic piston pump,German imported Rexroth pump,Rexroth A10VSO71DR hydraulic pump |
||
A10VSO71DR/32L-PPB22U99 A10VSO71DRF/32L-VPB22U00 A10VSO71DR/32L-VPB22U99 German imported Rexroth mechanical piston pump
Motor Type
Piston Motor
Displacement
42/55/75/100/130/10/250 cm³
Dimension (L×W×H)
Depend on Model
Maximum Flow Rate
Depend on Model
Power (W)
Depend on Model
Pressure
Depend on Model
Structure
Depend on Model
Cause
Solution
Motor rotation direction is reversed
Swap two phases of the motor power supply to correct rotation direction.
Swashplate angle is 0° (no displacement)
For DR control: Adjust the handwheel/lever to increase the swashplate angle. For EP control: Check if the electrical signal (0-10V/4-20mA) is normal.
Suction line is blocked/leaking
Clean or replace the suction filter; repair leaks in the suction line.
Oil level in the tank is too low
Add hydraulic oil to the recommended level (between the tank's upper/lower marks).
Internal wear (e.g., piston/cylinder block)
Overhaul the pump; replace worn parts (pistons, cylinder block, valve plate).
Noise Type
Possible Cause
Solution
Whistling
Cavitation (air in the suction line)
Check for suction line leaks; ensure oil level is sufficient; clean the suction filter.
Knocking
Shaft misalignment or coupling damage
Realign the pump and motor shafts; replace the damaged coupling.
Grinding
Bearing wear or foreign debris in the pump
Disassemble the pump; replace worn bearings; flush internal passages to remove debris.
Vibrating noise
Loose mounting bolts or swashplate jamming
Tighten mounting bolts to the specified torque; inspect the swashplate for jamming (clean or replace if needed).
Cause
Solution
Insufficient oil flow in the cooling system
Check the cooler fan/pump; clean the cooler's heat exchanger (remove dirt buildup).
Hydraulic oil viscosity is too high
Replace with oil of the correct viscosity (15-40 mm²/s at 40°C).
Internal leakage (e.g., worn valve plate)
Overhaul the pump; replace the valve plate and piston seals.
System pressure is too high (overloaded)
Reduce the system load; check if the relief valve is stuck open.
Contact Person: zixin