Product Details:
Contact Now
Chat Now
|
| Shafttype: | Splined Or Keyed Shaft | After Serive: | Online Video |
|---|---|---|---|
| Type: | Hydraulic Pump | Pump Shaft Position: | Horizontal |
| Material: | High-grade Steel And Aluminum Components | Structure: | Variable Piston Pump |
| Productname: | Rexroth Hydraulic Pump | ||
| Highlight: | A10VSO45DFR/31R-PPA12N00,A10VSO 45,Mechanical Hydraulic Pump |
||
A10VSO45DFR/31R-PPA12N00 A10VSO45DFR1/31L-PPA12N00 German Rexroth mechanical hydraulic equipment engineering hydraulic pump imported with original packaging.
Product Name
Hydraulic Piston Pump
Brand Name
REXROTH
Place of Origin
Fujian, China
Pump Type
Piston Pump
Material
Cast Iron
Application
Construction Machinery
Displacement
Depend on Model
Dimension (L*W*H)
Depend on Model
Maximum Flow Rate
Depend on Model
Power (W)
Depend on Model
Pressure
Depend on Model
Structure
Depend on Model
Weight
33 (Unit: Not Specified)
Warranty
1 Year
Package
Wooden Box
Showroom Location
None
![]()
• Daily: Check oil level (maintain 2/3-3/4 of the tank), case temperature (<90°C), and listen for abnormal noise; record pressure and flow values
• Weekly: Inspect all hose connections for tightness; clean the suction strainer and pressure gauge
• Monthly: Test pilot pressure (port X) and adjust to 35 bar if needed; check for oil contamination (use a contamination test kit)
• 6-month: Replace the return filter (25 μm) and send oil for analysis (check particle count and moisture)
• 12-month: Full disassembly--replace seals (kit R900912345), bearings (R900014567), and valve plates; measure piston-cylinder and swashplate wear
• 24-month: Replace the entire pump if wear exceeds 30% of allowable limits
• Preparations: Heat the oil to 40-50°C (reduces viscosity for thorough drainage); shut down the system and relieve pressure (open the pressure relief valve)
• Drainage: Open the tank drain valve and remove the suction strainer to drain residual oil (takes 15-20 minutes)
• Cleaning: Flush the tank with 5-10 L of new oil (circulate with a portable pump for 5 minutes); clean the strainer and suction line with compressed air
• Refilling: Use a filtered oil filler (10 μm) to add VG 46 oil to the tank; bleed air from the pump (jog motor 3 times)
• Post-check: Run the pump at low speed for 10 minutes, then take an oil sample to verify cleanliness (NAS 9 class)
Contact Person: zixin