Home ProductsRexroth Proportional Valve

4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M

I'm Online Chat Now

4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M

4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M
4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M

Large Image :  4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M

Product Details:
Place of Origin: Germany
Brand Name: Rexroth
Certification: ISO
Model Number: 4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M
Payment & Shipping Terms:
Minimum Order Quantity: negotiation
Price: negotiation
Packaging Details: wooden box
Delivery Time: negotiation
Supply Ability: negotiation
Contact Now Chat Now

4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M

Description
Warranty: One Year Rotation: Clockwise Or Counterclockwise
Mounting Type: Flange, Foot, And Face Drive Mode: Mechanically Driven Pump
Pumptype: Variable Displacement / Fixed Displacement Pump: Rexroth
Highlight:

4WRZ16 Rexroth

,

4WRZ16E3-150-7X Rexroth Proportional Valve

,

4WRZ16W6-180-7X Electro Hydraulic Valves

4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M Rexroth Germany imported hydraulic machinery proportional electro-hydraulic valve
Parameter Item Details
Product Name Pressure Relief Valves
Brand Name Rexroth
Dimension (L*W*H) 20*10*20 (Unit not specified, recommended to add mm/cm)
Weight 1.5 (Unit not specified, recommended to add kg)
Warranty 1.5 Year
Maximum Flow Rate 60 L/min
Maximum Pressure 315 bar
Pressure System Pressure / 315 bar
Power (W) 0.5 W
Structure Inside
Showroom Location None
Certification 3CE (Note: Standard certification is CE; confirm if it's a typo)
MOQ 1 Pc
4WRZ16E3-150-7X/6EG24N9ETK4/M 4WRZ16E3-150-7X/6EG24N9EK4/D3M 4WRZ16W6-180-7X/6EG24N9K4/D3M 0
  • 4WRZ32W9-520-7X/6EG24N9TK4/D3M
  • 4WRZ32W9-520-7X/6EG24N9ETK4/M
  • 4WRZ32W9-520-7X/6EG24N9K4/M
  • 4WRZ32W9-360-7X/6EG24N9TK4/D3M
  • 4WRZ32W9-360-7X/6EG24N9ETK4/M
  • 4WRZ32W9-360-7X/6EG24N9K4/M
  • 4WRZ32W8-520-7X/6EG24N9TK4/D3M
  • 4WRZ32W8-520-7X/6EG24N9ETK4/M
  • 4WRZ32W8-360-7X/6EG24N9TK4/D3M
  • 4WRZ32W8-360-7X/6EG24N9K4/M
  • 4WRZ32W6-360-7X/6EG24N9EK4/M
  • 4WRZ32W6-520-7X/6EG24N9TK4/D3M
  • 4WRZ32W6-520-7X/6EG24N9TK4/M
  • 4WRZ32W6-520-7X/6EG24N9ETK4/D3M
  • 4WRZ32W6-520-7X/6EG24N9ETK4/M
  • 4WRZ32W6-520-7X/6EG24N9EK4/D3M
  • 4WRZ32W6-520-7X/6EG24N9EK4/M
  • 4WRZ32W6-520-7X/6EG24N9K4/D3M
  • 4WRZ32W6-520-7X/6EG24N9K4/M
  • 4WRZ32W6-360-7X/6EG24N9TK4/D3M
  • 4WRZ32W6-360-7X/6EG24N9TK4/M
  • 4WRZ32W6-360-7X/6EG24N9ETK4/D3M
  • 4WRZ32W6-360-7X/6EG24N9ETK4/M
  • 4WRZ32W6-360-7X/6EG24N9EK4/D3M
  • 4WRZ32W6A520-7X/6EG24N9EK4/M
  • 4WRZ32W6-360-7X/6EG24N9K4/D3M
  • 4WRZ32E3-360-7X/6EG24N9K4/M
  • 4WRZ32E3-520-7X/6EG24N9TK4/M
FAQ
1.1 What safety precautions must be observed before installing the valve?

Safety is paramount during installation. Prior to any work, adhere to these non-negotiable guidelines:

  • Energy Isolation: Ensure the hydraulic system's power supply (pump motor) and the valve's electrical power are completely disconnected and locked out/tagged out (LOTO) to prevent accidental activation.
  • Pressure Relief: Fully relieve all pressure in the hydraulic lines connected to the valve. Open the system's pressure relief valve and actuate all hydraulic cylinders/motors to drain residual pressure--failure to do so may result in sudden fluid ejection or component movement.
  • Personal Protective Equipment (PPE): Wear safety goggles, oil-resistant gloves, and protective footwear to guard against oil splashes and mechanical hazards.
  • Environmental Protection: Place oil-absorbent pads around the work area to contain any spilled hydraulic fluid, preventing ground contamination and slips.
  • Tool Verification: Use only calibrated, appropriate tools (e.g., torque wrench, flare nut wrench) to avoid damaging valve ports or fasteners.
1.2 What system checks are needed before valve installation to avoid post-installation failures?

Conduct these pre-installation system assessments to ensure compatibility and reliability:

  • Pipeline Compatibility: Verify that the diameter and pressure rating of the hydraulic lines match the valve's port specifications (e.g., P/T/A/B ports). Undersized lines cause pressure drops; oversized lines waste space and increase fluid residence time.
  • Fluid Quality Test: Use a portable oil analyzer to check the hydraulic fluid's contamination level (per ISO 18/15 standard), water content (≤0.1%), and viscosity. Contaminated fluid will immediately damage the valve's precision spool and seals.
  • Mounting Surface Inspection: Ensure the valve's mounting flange (e.g., ISO 4401) is flat, clean, and free of burrs. A warped surface (tolerance >0.1mm per 100mm) will cause valve body distortion and internal leaks.
  • Electrical System Compatibility: Confirm the control system (PLC/DCS) can output a 0-800mA proportional signal and that the power supply can provide stable 24V DC with sufficient current (≥1A) to avoid signal degradation.

Contact Details
Xiamen Lang Ye Hydraulic Electromechanical Equipment Co., Ltd

Contact Person: zixin

Tel: +8613225988223

Send your inquiry directly to us (0 / 3000)