Home ProductsRexroth Plunger Pump

Mechanical Rexroth Plunger Pump A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00

I'm Online Chat Now

Mechanical Rexroth Plunger Pump A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00

Mechanical Rexroth Plunger Pump A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00
Mechanical Rexroth Plunger Pump A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00

Large Image :  Mechanical Rexroth Plunger Pump A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00

Product Details:
Place of Origin: German
Brand Name: Rexroth
Certification: ISO
Model Number: A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 1
Delivery Time: 1
Payment Terms: MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability: 1
Contact Now Chat Now

Mechanical Rexroth Plunger Pump A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00

Description
Productname: Rexroth Plunger Pump Mountingtype: Flange Mounted
Sealingtype: Mechanical Seals Or Packing Seals Maintenance: Requires Periodic Inspection And Seal Replacement
Manufacturer: Rexroth Displacement: Variable, Commonly 10-100 Cc/rev
Highlight:

Mechanical Rexroth Plunger Pump

,

Plunger Pump A4VSO40LR2

,

A4VSO40LR2 Plunger Pump

A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00 German Rexroth original hydraulic plunger pump mechanical engineering imported genuine product
  • Brand Name: Rexroth
  • Model: A4VSO Hydraulic Pump
  • Pump Type: Piston Pump
  • Warranty: 1 Year
  • Place of Origin: Fujian China
  • Material: Carbon Steel
  • MOQ: 1 Piece
  • After-sales Service: Line Support
  • Package: Wooden Case
  • Color: Customer's Request

A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00 German Rexroth original hydraulic plunger pump mechanical engineering imported genuine product.

Mechanical Rexroth Plunger Pump A4VSO40LR2/10L-PPB25N00 A4VSO40LR2/10L-PPB13N00 A4VSO40DRG/10L-PPB25N00 0
Model Number
A4VSO125DRG/22R-PPB13N00
A4VSO40LR2G/10L-PPB13N00
A4VSO71LR2/10R-VPB25N00
A4VSO40LR2G/10L-PPB25N00
A4VSO40DR/10L-PPB25N00
A4VSO40DR/10L-PPB13N00
A4VSO71EO2/10R-VPB25N00
A4VSO71EO2/10R-VZB13N00
A4VSO71EO2/10R-PZB13N00
A4VSO71EO2/10R-VPB13N00
A4VSO71EO2/10R-PPB13N00
A4VSO71DR/10R-VPB13N00
A4VSO71DR/10R-PPB13N00
A4VSO40EO2/10R-PZB25N00
A4VSO40EO2/10R-VZB13N0
A4VSO40EO2/10R-PZB13N00
A4VSO40EO2/10R-PPB13N00
A4VSO40DRG/10R-VPB13N00
A4VSO40EO1/10R-VPB25N00
A4VSO40EO1/10R-VZB13N00
A4VSO40EO1/10R-PZB13N00
A4VSO40EO1/10R-VPB13N00
A4VSO40EO1/10R-PPB13N00
A4VSO40LR2/10R-VPB25N00
A4VSO40LR2/10R-VZB13N00
A4VSO40LR2/10R-PZB13N00
A4VSO40LR2/10R-VPB13N00
A4VSO40LR2/10R-PPB13N00
A4VSO40DRG/10R-VPB25N00
A4VSO40DRG/10R-VZB13N00
A4VSO40DRG/10R-PZB13N00
A4VSO71LR2G/10R-VPB25N00
A4VSO40DFR/10R-PPB13N00
A4VSO40LR2G/10R-VPB25N00
A4VSO40LR2G/10R-VZB13N00
A4VSO40LR2G/10R-VPB13N00
A4VSO40LR2G/10R-PPB13N00
A4VSO40DR/10R-VZB13N00
A4VSO40DR/10R-PZB13N00
A4VSO40DR/10R-VPB13N00
A4VSO40DR/10R-PPB13N00
A4VSO40LR2G/10R-PZB13N00
A4VSO40DFR/10R-VPB13N00
A4VSO40DFR/10R-PZB13N00
A4VSO40DFR/10R-VZB13N00
A4VSO40DFR/10R-VPB25N00
On-Site Operation Nuances & Quick Fixes
Q1: The LR2 control knob becomes unresponsive after repeated adjustment --how to resolve this without disassembly?
A1: Unresponsiveness is typically caused by internal spool jamming or knob mechanical wear. Try these on-site fixes first: ① Knob Mechanical Reset: Pull the knob outward by 5mm and rotate it 360° clockwise, then push back in--this realigns the internal linkage that may have shifted; ② Control Port Flushing: Disconnect the pilot pressure line (port X) for 10 seconds, then reconnect--this purges minor debris blocking the control valve; ③ Pressure Shock Activation: Briefly increase the system pressure to 400 bar (within peak limit) and hold for 2 seconds, then release--this can free a stuck spool by hydraulic force; ④ Lubrication Injection: Inject 0.5ml of food-grade silicone lubricant (compatible with FKM seals) into the knob's side vent hole--avoid oil-based lubricants that contaminate hydraulic fluid. If these steps fail, disassemble the control valve to clean the spool (use diesel and compressed air).
Q2: How to quickly measure the pump's actual volumetric efficiency using only a bucket and stopwatch (no professional tools)?
A2: Use the "gravimetric flow method" for on-site efficiency testing: ① Preparation: Ensure the system is at operating temperature (40-60°C); have a 200L calibrated bucket and a digital stopwatch ready; ② Flow Measurement: Close all system bypass valves, direct the pump's pressure line output into the bucket, start the stopwatch when oil begins to flow, and stop when the bucket reaches 100L; record the time (t seconds); ③ Efficiency Calculation: Volumetric efficiency (ηv) = (Actual Flow / Theoretical Flow) × 100%. Actual Flow = (100L / t) × 3.6 (converts to L/min); Theoretical Flow = 71 cm³/r × Motor Speed (rpm) ÷ 1000. For example, at 1500 rpm, Theoretical Flow = 106.5 L/min; if 100L fills in 110 seconds, Actual Flow = 32.7 L/min, ηv = 30.7% (indicates severe internal leakage); ④ Benchmark: ηv ≥95% = normal; 90-95% = minor wear; <90% = require maintenance. This method has an error margin of ±3%--sufficient for on-site judgment.

Contact Details
Xiamen Lang Ye Hydraulic Electromechanical Equipment Co., Ltd

Contact Person: zixin

Tel: +8613225988223